INSPECTION AND SERVICE

To Clean the Heat Exchanger

1

With outer case and base panel removed and
the power isolated from the appliance,
remove the cover panel (A) by removing the
retaining screw (B).

2

Remove clip (C) from gas valve outlet.
Pull gas adjustment assembly (D) free from
the plastic connection on the gas valve.
Pull gas adjustment assembly (D) forward to
clear case.

Removing Siphon
3.1
Undo plastic nut (E) on the siphon outlet.

Drop condensate tube away from siphon.

3.2 Remove hose (F).
3.3 Remove siphon

Siphon

The siphon body is transparent so contents
can be examined for any blockage.
If necessary flush with clean water.

1

A

B

2

C

D

3.3

3.2

3.1

F

E

INSPECTION AND SERVICE

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 107 336b (11/05)

38

SER

V

IC

IN

G

&

SP

A

RES

COMBUSTION TESTING MUST BE CARRIED
OUT BY A COM PETE NT PE R SON. IT M UST
NOT BE ATTEMPTED UNLESS THE PERSON
CARRYING OUT THE COMBUSTION CHECK
I S E Q U I P P E D W I T H A C O M B U S T I O N
ANALYSER CONFORMING TO BS 7927 AND
IS COMPETENT IN IT’S USE.

I M P ORTANT: I F TH E JOI NT
BETWEEN THE AIR/GAS MANIFOLD
AN D TH E H EAT E XCHANG E R I S
DISTURBED THE SEALING GASKET
MUST BE REPLACED.