beautypg.com

Reference, 9. 3 user mode 03 (cold sleep mode setting) – Konica Minolta KIP Color 80 User Manual

Page 51

background image

1-46

2. 9. 3 User Mode 03 (Cold Sleep Mode setting)


The timer setting for the Cold Sleep Mode is available.






























[Operation]

1. Press the Menu Key 3 times to select the User Mode 03.









2. Press the Enter Key. The setting value on the right hand flashes and becomes changeable.





Menu

Enter

Online



(1) Cold Sleep Mode is a kind of power saving mode that can save more power than Warm
Sleep Mode. It works when the KIP Color 80 does not print for the time the timer specifies.
Power consumption is reduced greatly by completely shutting off supplying the power to
the fuser unit.
The Cold Sleep Mode will be cancelled automatically when a print job or a copy job is sent
from the outer device. However it may take time until the KIP Color 80 starts printing as it
needs to recover enough temperature on the fuser. (Print does not start until the KIP Color
80 becomes ready recovering enough temperature.) Note that the Cold Sleep Mode will
require
longer recovering time than Warm Sleep.

(2) Cold Sleep Mode works prior to the Warm Sleep Mode.
Supposing the timer is set as;
“30 minutes” for the Warm Sleep Mode
“15 minutes” for the Cold Sleep Mode
In this case the Cold Sleep Mode works 15 minutes later but the Warm Sleep Mode does
not work even if 30 minutes passes.
Supposing the timer is set as;
“15 minutes” for the Warm Sleep Mode
“30 minutes” for the Cold Sleep Mode
In this case the Warm Sleep Mode works 15 minutes later and the Cold Sleep Mode works
30 minutes later.