5.14.5 Register Read/Write
The Read/Write informs the command decoder that a register access is required. During a read operation, the ad-
dressed register is loaded into an output buffer and clocked out by SCLK. During a write operation, the data is
clocked into an input buffer and transferred to the addressed register upon completion of the 24
th
SCLK.
W/R
Write/Read control
0 = Read
1 = Write
RA[4:0]
Register address bits (bits 5 through 1) of the read/write command.
Address
RA[4:0]
Name
Description
0
00000
Config
Configuration
1
00001
I
DCoff
Current DC Offset
2
00010
I
gn
Current Gain
3
00011
V
DCoff
Voltage DC Offset
4
00100
V
gn
Voltage Gain
5
00101
Cycle Count
Number of A/D conversions used in one computation cycle (N)).
6
00110
PulseRateE
1,2
Sets the E1 and E2 energy-to-frequency output pulse rate.
7
00111
I
Instantaneous Current
8
01000
V
Instantaneous Voltage
9
01001
P
Instantaneous Power
10
01010
P
Active
Active (Real) Power
11
01011
I
RMS
RMS Current
12
01100
V
RMS
RMS Voltage
14
01110
P
off
Power Offset
15
01111
Status
Status
16
10000
I
ACoff
Current AC (RMS) Offset
17
10001
V
ACoff
Voltage AC (RMS) Offset
18
10010
PulseRateE
3
Sets the E3 energy-to-frequency output pulse rate.
19
10011
T
Temperature
20
10100
SYS
Gain
System Gain
21
10101
PW
Pulse width register for mechanical counter output mode
22
10110
PulseWidth
Pulse width register for E3 energy pulse output
23
10111
VSAG
Duration
Voltage Sag Duration
24
11000
VSAG
Level
Voltage Sag Level Threshold
25
11001
LoadIntv
No load threshold interval (detection window)
26
11010
Mask
Interrupt Mask
27
11011
LoadMin
No Load Threshold
28
11100
Ctrl
Control
29
11101
T
Gain
Temperature Sensor Gain
30
11110
T
off
Temperature Sensor Offset
31
11111
S
Apparent Power
Note: For proper operation, do not attempt to write to unspecified registers.
B7
B6
B5
B4
B3
B2
B1
B0
0
W/R
RA4
RA3
RA2
RA1
RA0
0