7 adc control 1 (address 0fh), 1 va select, 2 enable high-pass filter – Cirrus Logic CS4244 User Manual
Page 51: 3 inv. adcx, 8 adc control 2 (address 10h), 1 mute adcx, 2 power down adcx, Power down adcx, Bits, Cs4244

DS900F1
51
CS4244
6.7
ADC Control 1 (Address 0Fh)
6.7.1
VA Select
Scales internal operational voltages appropriately for VA level. Configuring this bit appropriately for the
VA voltage level used in the application is imperative to ensure proper operation of the device.
6.7.2
Enable High-pass Filter
Enables high-pass filter for the ADC path.
6.7.3
Inv. ADCx
Inverts the polarity of the ADCx signal.
6.8
ADC Control 2 (Address 10h)
6.8.1
Mute ADCx
Mutes the ADCx signal
6.8.2
Power Down ADCx
Powers down the ADCx path.
7
6
5
4
3
2
1
0
Reserved
Reserved
VA_SEL
ENABLE HPF
INV. ADC4
INV. ADC3
INV. ADC2
INV. ADC1
VA_SEL
Must be set when VA is:
0
3.3 VDC
1
5 VDC
ENABLE HPF
High Pass Filter is:
0
Disabled
1
Enabled
INV. ADCx
ADCx Polarity is:
0
Not Inverted
1
Inverted
7
6
5
4
3
2
1
0
MUTE ADC4
MUTE ADC3 MUTE_ADC2 MUTE ADC1
PDN ADC4
PDN ADC3
PDN ADC2
PDN ADC1
MUTE ADCx
ADC is:
0
Not Muted
1
Muted
PDN ADCx
ADC is:
0
Powered Up
1
Powered Down