Next Advance SP1800 User Manual
Page 3
![background image](/manuals/466043/3/background.png)
NEXT>>>ADVANCE
www.nextadvance.com
SP1600/1800 Programmable Syringe Pump
Publication #1200-02
ii
9/15/04
Table of Contents
1.
General Information...........................................................................................................1
1.1
Warnings
!
and Cautions
!
................................................................................................1
1.2
Disclaimer ....................................................................................................................................1
1.3
Warranty .....................................................................................................................................2
1.4
Packing List .................................................................................................................................2
2.
Overview ..............................................................................................................................2
2.1
Glossary of Terminology and Concepts ....................................................................................3
3.
Setup ....................................................................................................................................5
4.
Loading Syringes.................................................................................................................5
5.
User Interface......................................................................................................................6
5.1
Entering Values...........................................................................................................................6
5.2
LCD Display ................................................................................................................................6
5.3
LEDs.............................................................................................................................................6
5.4
Arrow and Decimal Point Keys .................................................................................................7
5.4.1
Decimal Point Key............................................................................................................................... 7
5.5
‘Diameter’ and ‘Setup’ Key .......................................................................................................8
5.6
‘Rate’ and ‘Program Phase #’ Key............................................................................................8
5.6.1
Pumping Rate Units............................................................................................................................. 8
5.6.2
Program Entry Mode ........................................................................................................................... 8
5.7
‘Volume’ and ‘Program Function’ Key....................................................................................8
5.7.1
Disabling “Volume to be Dispensed”.................................................................................................. 9
5.7.2
Program Entry Mode ........................................................................................................................... 9
5.8
Pumping Direction Key ..............................................................................................................9
5.9
‘Start’/’Stop’ Key........................................................................................................................9
5.10
‘Program Phase #’ (Number) Key .......................................................................................10
5.11
‘Program Function’ Key.......................................................................................................10
5.11.1
Program Phase Function Parameter ................................................................................................... 10
5.12
‘Setup’ Key.............................................................................................................................10
5.13
Special Power-Up Functions.................................................................................................11
5.13.1
Firmware Version Display................................................................................................................. 11
5.13.2
Reset Pumping Program .................................................................................................................... 11
5.13.3
Default Program Pre-Load................................................................................................................. 11
5.14
Error and Alarm Messages. .................................................................................................11
5.15
Status Messages .....................................................................................................................12
6.
Operation...........................................................................................................................13
6.1
Syringe Inside Diameter ...........................................................................................................13
6.1.1
Default Volume Units........................................................................................................................ 13