669

39

.0

5 D

/G

B

06

/2

00

6

Universal IS Pressure Transmitter UniTrans

Technical Data

Subject to change due to technical modifications.

© Copyright WIKA Alexander Wiegand GmbH & Co. KG / Germany

WIKA Alexander Wiegand GmbH & Co. KG · Alexander-Wiegand-Str. · 63911 Klingenberg · (09372) 132 - 710 · Fax - 706 · E-mail: [email protected] · www.wika.de

106

6.6

Process Conditions

6.7

Safety-related nominal values for IS protection conditions

Storage temperature

– 40 °C ... + 85 °C
(– 35 °C ... 80 °C with display)

Climate class

D per DIN IEC 654-1

Ingress protection per EN 60 529

IP 65 for plastic case
IP 67 for aluminium case

EMC per

EN 50 081-2, EN 50 082-2,
NAMUR NE 21

Medium temperatures

– 30 °C ... + 105 °C

Please consider the safety related
values according to EC-Type
Examination Certificate (see chapter 3)

-protection: The instruments are approved for IS zones, which require the

categories 1/2G, 2G,3G.
Dust approval 1/2D, 2D, 3D is available as an option.

Output signal

4 ... 20 mA, two-wire, optionally with
modulated HART signal

Ignition protection class

Available as an option

EEx ia IIC T4

EEx ia IIC T5 / T6

IP 6X T130°C / 95°C / 80°C

Certificate no. (display)

(DMT 99 ATEX E 091 U)

Certificate no. (pressure transmitter)

(DMT 99 ATEX E 093)

Power supply Ui

30 V DC

30 V DC

Short-circuit current Ii

100 mA

93 mA

Maximum load Pi

750 mW

697 mW

Medium temperature

-40°C ... +105°C

-40°C ... +60°C

Ambient temperature

-40°C ... +70°C

-40°C ... +60°C

Internal capacity Ci

9 nF

Internal inductivity Li

very small