beautypg.com

Gb 2. safety / 3. specifications, Specifications – WIKA HP-2 User Manual

Page 8

background image

8

WIKA operating instructions pressure transmitter, model HP-2

11379180.03 09/2013 GB/D/F/E

GB

2. Safety / 3. Specifications

Explanation of symbols

CE, Communauté Européenne

Instruments bearing this mark comply with the relevant European directives.

3. Specifications

WARNING!

When designing the system, please note that the values given (e.g. burst

pressure, overpressure limit) are dependent upon the material and thread

used.

Measuring ranges

Relative pressure

bar Measuring range

0 ... 1,600

0 ... 2,500

0 ... 4,000

0 ... 5,000

Overpressure limit

2,300

3,500

5,000

6,000

Burst pressure

4,000

6,000

8,000

10,000

Measuring range

0 ... 6,000

0 ... 7,000

0 ... 8,000

0 ... 10,000

Overpressure limit

7,000

8,000

10,000

11,000

Burst pressure

11,000

11,000

12,000

12,000

Measuring range

0 ... 12,000

0 ... 15,000

Overpressure limit

12,500

15,500

Burst pressure

14,000

16,000

psi Measuring range

0 ... 23,000

0 ... 36,000

0 ... 58,000

0 ... 72,000

Overpressure limit

33,300

50,500

72,500

87,000

Burst pressure

58,000

87,000

116,000

145,000

Measuring range

0 ... 87,000

0 ... 100,000

0 ... 115,000

0 ... 145,000

Overpressure limit

101,500

116,000

145,000

159,000

Burst pressure

159,500

159,500

174,000

174,000

Service life

On request, since the service life depends on the actual pressure profile.

Despite its excellent load cycle stability a permanent load cycle stability is only given

conditionally. This is due to the extreme loadings faced by the highly pressurised

materials. This applies particularly to dynamic applications. Accordingly, the pressure-

loaded parts of the HP-2 are considered as wear parts that are not covered by the

warranty.