VP-771 - The VP-771 RS-232 Communication Protocol
77
77
VOLUME-PARAMETER
= output volume parameters:
[VALUE] either positive or negative digits (minus sign precedes negative values).
“+” increase current value,
“-“ decrease current value
Window
customization
WIN-CUST WINDOW, HPOS,
HW , VPOS, VH
WIN- CUST WINDOW, HPOS,
HW , VPOS, VH RESULT
Parameters Description: fast window customization
[WINDOW] “0” for main window; “1” for PiP window
[HPOS] horizontal position value
[HW] horizontal width value
[VPOS] vertical position value
[VH] vertical height value
Set dual window state
PIP PIP-MODE
PIP PIP-MODE RESULT
Get dual window state
PIP?
PIP PIP-MODE
Parameters Description:
PIP-MODE
= Dual window state:
"0" or "off" for single window.
"1" or "on" to for dual window.
Identification commands
Command
Syntax
Response
Protocol
Handshaking
#CR
~OK CRLF
Read device model
MODEL?
MODEL MACHINE_MODEL
Read device serial
number
SN?
SN SERIAL_NUMBER
Read device
firmware version
VERSION?
VERSION MAJOR .MINOR
.BUILD .REVISION
Read device build
date
BUILD-DATE?
BUILD-DATE YYYY/MM/DD
HH:MM:SS
Read device protocol
version
PROT-VER?
PROT-VER 3000:MAJOR
.MINOR
Set machine name
NAME MACHINE_NAME
NAME MACHINE_NAME
RESULT
Read machine name
NAME?
NAME MACHINE_NAME
Reset machine name
to factory default*
NAME-RST
NAME-RST RESULT
Network settings commands
Network settings commands require admin authorization
Command
Syntax
Response
Set IP Address NET-IP IP_ADDRESS
NTIP
NET-IP IP_ADDRESS RESULT