Kramer Electronics VP-771 User Manual
Page 75
70
VP-771 - The VP-771 RS-232 Communication Protocol
1st
Level
2nd Level
3rd Level
4th Level
Range
Func. Note
Bypassed Group
Unmute
0
295
Mute
1
Process
Deinterlacing
Method
Line Doubler
0
311
Volatile parameter
unavailable in
progressive scan
Motion Adaptive 1
Sync
Current Field
0
312
Unavailable in
progressive scan.
Older Field
1
Film Mode
Off
0
320
Unavailable in
progressive scan
Follow Input
1
24PsF Mode
2
Diagonal
Correction
0:3
330
Unavailable in
progressive scan.
Unavailable when
deinterlacing sync is
older field
MD Sensitivity
LEVEL1
0
340
Unavailable in
progressive scan
LEVEL2
1
LEVEL3
2
LEVEL4
3
LEVEL5
4
Picture
Brightness
-400:400
410
In the OSD menu
the range appears
as -80:80
Contrast
0.1:1.6
420
Color
0.1:1.6
430
Color
Correction
Blue
0:4
441
Green
0:4
442
Flesh
0:4
443
Black Level
-80:80
450
Gamma Mode Gamma Off
0
460
Gamma 0.4
1
Gamma 0.8
2
Gamma 1.2
3
Gamma 1.6
4
Gamma 2.0
5
Gamma 2.4
6
Gamma 2.8
7
Dither
Mode0: Disable error diffusion
0
470
Mode1: In-frame 8:6 conversion
1
Mode2: Intra-frame 8:6 conversion
2
Mode3: In-frame 10:8 conversion
3
Mode4: Intra-frame 10:8 conversion
4
Mode5: In-frame 12:10 conversion
5
Mode6: Intra-frame 12:10 conversion
6
Auto Adjust
0:1
480
Self-clearing
Enhance H Sharpness
-10:10
510
V Sharpness
-10:10
520
Noise
Reduction
Mosquito NR
0:3
531
unavailable in
progressive scan
Combing NR
0:3
532