Digico waves operation – DiGiCo Waves MultiRack SoundGrid User Manual
Page 33
DiGiCo Waves Operation
1-33
a)
Racks: Select a Rack or multiple racks you want to set to Recall Safe. Touch the “Set” button or Right click on any of the selected
Racks and choose Recall Safe from the pull-down menu. Recall Safed Racks glow blue:
b)
Plug-ins: Select the plug-in you want to set to Recall Safe. Touch the “Set” button or Right click on any of the selected plug-ins
and choose Recall Safe from the pull-down menu. Recall Safe plug-ins glow blue:
c)
To remove a Rack or plug-in from Recall Safe mode, select the respective Rack or plug-in and touch the “Unset” button or de-
select Recall Safe from the right click pull-down menu in Recall Safe mode.
d)
Plug-ins or Racks that are set to Recall Safe can be edited. However, their Recall Safe status can be viewed only while in Recall
Safe mode. Selecting Recall Safe in the Snapshots menu does not activate or deactivate Recall Safe. Rather, it only allows you to
see plug-ins and Racks and set them to Recall Safe. When you turn Recall Safe mode off, Racks and plug-ins which have been
Recall Safe remain so; they just don’t glow blue.
e)
When a Rack is Recall Safed, all the plug-ins within that Rack are affected, i.e. are effectively recall-safed as well.