beautypg.com

6. using ufc (universal flex coms) function – A&D Counting Scale HC-15Ki User Manual

Page 53

background image

51

13-6. Using UFC (Universal Flex Coms) Function

‰ The UFC function allows you to print out as you format the printer (UFC format).

‰ The scale can store the UFC format as text data. It will include parameters to

replace with the count data, weight data and so on.

‰ The maximum number of text data is 384 characters.

‰ Terminator for the “PF” command is "C

R

" or "C

R

L

F

".

‰ Using “PF” command, the text data has to be sent to the scale from the computer in

advance. Then, connect the scale with the printer.

‰ When the PRINT key is pressed or by auto-print mode A/B, the scale will send the

stored text data with the parameters replaced by the original data.

Store Text Data into the Scale Memory

Command P F

, $ P C ,

T E X T

,

# 2 0

, $ S P

½

2

,

&

$ C R , $ L F

,

$ W T

,

$ C R ,

$ L F C L

F

Reply ACK C L

F

The “PF” command sends text data that will include:

‰ Parameters for the scale data and control codes

Parameter

Data & Code

Parameter

Data & Code

$PC

Count

$CD

ID number in use

$WT Weight

$CP Comparator

result

$UW

Unit weight in use

$CM

Comma

$TR

Tare weight in use

$SP

Space

$TL

Total count

$CR

Carriage Return

$AN

Accumulation numbers

$LF

Line Feed

These parameters must be used in capital letters.

‰ ASCII text string

Text string is described in single quote marks as ‘Data’.
The single quote itself is written as ’’(2 single quotes).

Example: Text ‘ABC’ is described as ‘’’ABC’’’.

‰ The ASCII hexadecimal code

The ASCII hexadecimal codes are written in the form “#" + 2 hexadecimal digits.
This will mainly be used to send control codes that can’t be described as a text string.

Example: #04

“EOT” of ASCII code

‰ Repeat data

The control codes $SP, $CR and $LF can be used with “ + maximum 2 digit
number”. That code will be repeated the number of times designated.

Example: $LF 9

Repeat “$LF” 9 times.

$SP 12

Put 12 “Spaces”.

‰ Link mark “&”

If you will send more than 2 lines of data, attach “&” to the end of the first line. Then,
the scale considers the data to be continued.