A&D Counting Scale HC-15Ki User Manual
Page 26
24
Automatic M+ Accumulation Mode
M+ Accumulation can also be done automatically each time you count a different
batch, As soon as you have a stable count, it will be added to the M+ memory and
the scale will beep
. The weight display will have to return to near zero before
another count can be added.
Automatic M+ accumulation is set by F-Function f-03-01 at “1”.
Only positive counts can be added. If F-Function f-03-02 is set at “1” (to accept
negative count data), it will be ignored.
Once there is an automatic M+ accumulation, the display must return to less than
+5d before another count can be accumulated.
6-2. Viewing the M+ TOTAL
1. Press the TOTAL key.
The count display will show the total
count and the TOTAL annunciator
will come ON.
The number of additions to the M+
memory is also shown.
2. Press the TOTAL key again.
The display will return to normal.
6-3. Clearing the M+ TOTAL
1. Press and hold the C key, then press
the TOTAL key – release both.
2. The scale will clear the M+ memory, and the TOTAL annunciator and the M+
annunciator will go OFF.
6-4. The M- Function
The scale can subtract count data from M+ memory by using the ½ key.
Set the F-Function f-09-01=‘1’ to use the ½ key as M- key.
This function is not to clear the last M+ addition, but to subtract count data instead
of addition. The number of additions is increased.
There is no automatic M- function.
TOTAL
C
+
The RESET key does not clear the total data.
The total data is held in memory, even if AC/Battery power to
scale is interrupted.
TOTAL
TOTAL Count
Number of additions to M+ memory
888.8
1234
COUNT
TOTAL
M+
TOTAL
annunciator
comes ON.
WEIGHT UNIT WEIGHT
STABLE
TARE
ENTERED
ZERO
888
0.000
8
8
8.8.8.8.8
7