Automatic M+ Accumulation Mode

‰ M+ Accumulation can also be done automatically each time you count a different

batch, As soon as you have a stable count, it will be added to the M+ memory and
the scale will beep

‘. The weight display will have to return to near zero before

another count can be added.

Automatic M+ accumulation is set by F-Function f-03-01 at “1”.

Only positive counts can be added. If F-Function f-03-02 is set at “1” (to accept

negative count data), it will be ignored.

Once there is an automatic M+ accumulation, the display must return to less than

+5d before another count can be accumulated.

6-2. Viewing the M+ TOTAL

1. Press the TOTAL key.

The count display will show the total
count and the TOTAL annunciator
will come ON.
The number of additions to the M+
memory is also shown.

2. Press the TOTAL key again.

The display will return to normal.

6-3. Clearing the M+ TOTAL

1. Press and hold the C key, then press

the TOTAL key – release both.

2. The scale will clear the M+ memory, and the TOTAL annunciator and the M+

annunciator will go OFF.

6-4. The M- Function

‰ The scale can subtract count data from M+ memory by using the ½ key.

‰ Set the F-Function f-09-01=‘1’ to use the ½ key as M- key.

This function is not to clear the last M+ addition, but to subtract count data instead
of addition. The number of additions is increased.
There is no automatic M- function.

TOTAL

C

+

‰ The RESET key does not clear the total data.

‰ The total data is held in memory, even if AC/Battery power to

scale is interrupted.

TOTAL

TOTAL Count

Number of additions to M+ memory

888.8

1234

COUNT

TOTAL

M+

TOTAL
annunciator
comes ON.

WEIGHT UNIT WEIGHT

STABLE

TARE

ENTERED

ZERO

888

0.000

8

8

8.8.8.8.8

7

This manual is related to the following products: