Programming the Watchdog Timer

In order to program the watchdog timer, you must write a program
which writes I/O port address 443 (hex). The output data is a
value of time interval. The value range is from 01(hex) to 3F(hex),
and the related time interval is 1 sec. to 63 sec.

Data

Time Interval

01

1 sec.

02

2 sec.

03

3 sec.

04

4 sec.

.
.
.

3F

63 sec.

After data entry, your program must refresh the watchdog timer
by rewriting the I/O port 443 (hex) while simultaneously setting
it. When you want to disable the watchdog timer, your program
should read I/O port 043 (hex).

The following example shows how you might program the
watchdog timer in BASIC:

10

REM Watchdog timer example program

20

OUT &H443, data REM Start and restart the

watchdog

30

GOSUB 1000 REM Your application task #1

40

OUT &H443, data REM Reset the timer

50

GOSUB 2000 REM Your application task #2

60

OUT &H443, data REM Reset the timer

70

X=INP (&H043) REM Disable the watchdog

timer

80

END