Serial proxpro reader ™ specifications – HID Serial ProxPro Reader Installation Guide User Manual
Page 10
________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
http://www.prox.com Serial ProxPro Reader Installation Manual 5352-900 Rev F 9 of 9
Serial ProxPro Reader™ Specifications
Read Distance - using ProxCard II
Over all Operating Limits, minimum (@12VDC))
5.0 inches (12.5 cm)
Non-Metallic Mounting, typical (@12VDC)
7.0 inches (17.6 cm)
Mounted on Metal, typical (@12VDC)
5.0 inches (12.5 cm)
Overall Operating Limits, minimum (@24VDC)
5.0 inches (12.5 cm)
Non-Metallic Mounting, typical (@24VDC)
7.5 inches (19 cm)
Mounted on Metal, typical (@24VDC)
5.5 inches (15.2 cm)
Regulatory Approvals and Certifications
Underwriters Laboratories listing under UL 294, Access Control Unit Accessory, Indoor and Outdoor
UK Type Approval
German General License Type Approval per RTP letter, Vfg 70/1998, dated 30 June 1998
CE Mark - See declaration of conformity
FCC Certification
FCC Compliance Statement : This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions : 1) This device may not cause harmful interference, 2) This device must
accept any interference received, including interference that may cause undesired operation.
The reader is intended to be powered from a limited power source output of a previously certified
power supply.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Environmental Characteristics
Designed for listing under UL 294 “Standard for Access Control System Units”
Operating Temperature Range
-30
o
C to 65
o
C (-22
o
F to 150
o
F)
Storage Temperature Range
-40
o
C to 85
o
C (-40
o
F to 185
o
F)
Operating Humidity Range
5% to 95% non-condensing
Operating Vibration Limit
.04 g
2
/Hz 20-2000Hz
Operating Shock Limit
30g, 11mS, Half Sine
Enclosure Material
UL Recognized Lexan Polycarbonate
Weight 11.3oz
(310gms)
Power Requirements
Power supply
Linear type recommended
Operating Voltage Range (+DC)
10VDC -28.5VDC
Absolute Maximum (+DC non-operating)
31.4VDC
Maximum Average Current 12V/24V
120mA/150mA
Transient Protection (all terminals)
8,000 volts
Reverse Voltage Protection
YES
Input Voltage (maximum data-0/1 lines)
28.5VDC
Input Voltage (maximum interface lines)
28.5VDC
Operating Parameters
Excitation Frequency
125KHz
Duty Cycle (alternate power level rate)
20% @ 60mS period
Read and Report Speed (26 bit Card)
100mS
RS232 - Maximum Cable Distance to Host
50 - 200 feet (61 meters)
RS422 - Maximum Cable Distance to Host
4000 feet (1230 meters)
RS485 - Maximum Cable Distance to Host
4000 feet (1230 meters)
LED Type Bi-colored Red/Green
LED Control (default)
internal control enabled
Beeper Control (default)
internal control enabled
Anti-Pass Back Delay (default)
1 second
NOTES: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES. ALL LOCAL, STATE AND
NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.