Minimum Clearances: Boilerless steamer requires the following minimum clearances

to any surface, combustible or noncombustible.

Right Side

2 inches

Left Side

2 inches

Rear

6 inches

Steam Free Zone: The boilerless steamer can be damaged by steam from external

sources. Do not install the steamer over a steam venting drain. Ensure that steam is

not present in an area bounded by the footprint of the steamer and a circle 18 inches

in radius about the right rear corner of the steamer (see figure at left).

1. Electrical Supply Connection

Current and power demands for each unit are as shown above.

A. Panel Removal - Right Side

Open the wiring and control panel by removing screws from the right side

panel. Slide the panel forward and set it aside.

B. Supply Voltage

The unit must be operated at the rated name plate voltage. The name plate

can be found on the rear of the unit.

C. Phase Selection

Refer to steamer wiring diagram and element wiring on pages 19 and 20

for wiring information.

D. Terminal Block

The terminal block for incoming power is located at the back of the control

compartment. The ground terminal is located in the wiring compartment

near the terminal block.

E. Supply Wire

The equipment grounding wire must comply with the National Electrical

Code (NEC) requirements. The wiring diagram on the inside of the unit’s

right side cover gives directions for proper connection of the terminal block

jumpers. The wire must be used or the unit will not meet Underwriters

Laboratories and NEC requirements. The electric hole is sized for a one-

inch conduit fitting.

F. Branch Circuit Protection

Each boilerless steamer, including individual units of stacked models,

should have its own branch circuit protection and ground wire.

CAUTION

DO NOT INSTALL THE UNIT WITH THE REAR

VENTS BLOCKED OR WITHIN 2 INCHES

OF A HEAT SOURCE SUCH AS A BRAISING

PAN, DEEP FAT FRYER, CHARBROILER OR

KETTLE. TO AVOID DRAINAGE PROBLEMS,

LEVEL THE UNIT FRONT TO BACK, AND

PITCH SLIGHTLY TO THE FRONT.

Installation

WARNING

THE UNIT MUST BE INSTALLED BY

PERSONNEL WHO ARE QUALIFIED TO

WORK WITH ELECTRICITY AND PLUMBING.

IMPROPER INSTALLATION CAN CAUSE

INJURY TO PERSONNEL AND/OR DAMAGE TO

THE EQUIPMENT. THE UNIT MUST BE

INSTALLED IN ACCORDANCE WITH

APPLICABLE CODES.

CAUTION

EACH UNIT MUST HAVE A SEPARATE

GROUND WIRE FOR SAFE OPERATION.

ELECTRICAL SUPPLY CONNECTION

Model

kW

Rating

Rated Current Demand Per Cavity (Amperes)

208V, 1-Ph

208V, 3-Ph

240V, 1-Ph

240V, 3-Ph

480V, 3-Ph

3-Pan

9

44

25

38

22

11

5-Pan

12

58

34

50

29

15

10-Pan

21

NR

59

NR

51

26

WARNING

TO AVOID DAMAGE OR PERSONAL INJURY,

FOLLOW THE WIRING DIAGRAM EXACTLY.