beautypg.com

Maintenance – Blodgett SBC-E Series User Manual

Page 14

background image

12

OM-SBC-E

Maintenance

The boilerless steamer is designed for minimum maintenance and no user adjust-

ments should be necessary. Certain parts may need replacement after prolonged

use. If there is a need for service, only Authorized Service Agents should perform the

work.

If steam or condensate is seen leaking from around the door, take the following

steps:

1. Check the door gasket. Replace it if it is cracked or split.

2. Inspect the cooking chamber drain to be sure it is not blocked.

3. Adjust the door latch pin to allow for changes that might occur as the gasket

ages.

a. Loosen the lock nut at the base of the latch pin, then turn the latch pin

1/4 turn clockwise, and tighten the lock nut.

b. After adjustment, run the unit to test for further steam leakage.

c. If there is still leakage, repeat the adjustment

d. Continue adjusting the pin clockwise until the door fits tightly enough to

prevent leakage. The hinge may also be adjusted.