Operation – Blodgett SBC-E Series User Manual
Page 10
![background image](/manuals/428377/10/background.png)
8
OM-SBC-E
Operation
A. Controls
Operator controls are on the front right of the unit.
The control panels have the following touch pads and indicator lights:
1. The TIME display shows the remaining cooking time. It displays three
dashes in MANUAL mode.
2. The ON/OFF rocker switch gets the unit ready for use or shuts it off.
3. The READY indicator light indicates the unit has achieved the ready
temperature.
4. Hour meter records cumulative hours of operation.
5. The FAULT display shows the current fault.
The push button operations:
1. In the STOP mode the steam generator stays at a low boil or ready
temperature.
2. When the TIMED button is pushed , the TIMED light will illuminate and
time can be set by turning the TIMER knob (cook time can be increased or
decreased at any time by turning the timer knob). The unit steams until the
timer counts down to zero and the temperature drops to ready. At that time
the STOP light illuminates and a beeper sounds.
3. When the MANUAL button is pushed, the unit steams continuously. The
MANUAL light will stay illuminated.
4. CANCEL button should be pushed to stop beeping.
For service/support call
866-518-3977
www.blodgett.com
170155 REV. A
READY
HOURS
ON
OFF
MANUAL
TIMED
STOP
CANCEL
TIME display
TIMER knob
MANUAL button
and indicator
TIMED button
and indicator
STOP button
and indicator
CANCEL button
and indicator
FAULT display
READY indicator
ON/OFF
rocker switch
Hour meter