Installation, Electrical connection – Blodgett 1415 User Manual
Page 6
4
Installation
Electrical Connection
Ovens are supplied for operation on 208 volt or 220-240
volt installation. The thermostat, indicator light and related
switches are interconnected through one power source
supplied to the oven.
Before making any connection to this oven, check the rat-
ing plate attached to the bodyback to assure that the volt-
age, phase and KW rating are compatible with the electri-
cal supply. See diagram.
All ovens, when installed, must be connected and electri-
cally grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-Latest Edition and/or Canadian Electric
Code CSA C22.1 as applicable.
Wiring diagrams are located on the bodyback.
The supply conduit enters through the rear of the oven
and electrical connection is made to the terminal block
secured to the panel at the back of the control compart-
ment. Electrical connection sizes for a double 1400 oven
are shown in “Electrical Connection AWG” column of the
Electrical Specifications found on page 2 of this manual.
Wiring is sized for 75_C copper wire at 125% of rated
input. Reference is from the National Electric Code ANSI/
NFPA 70- Latest Edition.
Wiring Label
Rating Plate
Wiring
Schematic
Installation Instructions
“Do not install closer than 2 inches to
any side or rear wall”
Figure 1