beautypg.com

Installation, Utility specifications – Blodgett BLCM User Manual

Page 7

background image

5

Installation

Utility Specifications

PLUMBinG sPeCiFiCATions

WATeR
Water pressure

36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure

Water connection

3/4” garden hose cold water

Water quality requirements

TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: 0 ppm
pH: 7.0-8.5

DRAinAGe
Drain type

Atmospheric Vented Drain

Drain connection

2.00” (50.8mm) Copper

Maximum water drain temperature 140ºF (60ºC)

RATinGs - GAs ovens

Model

Gas Type

input

voltage

Phase

Amps

BLCM-61G

Natural

58,000 BTU

115

1

9

Propane

58,000 BTU

115

1

9

BLCM-101G

Natural

87,000 BTU

115

1

9

Propane

87,000 BTU

115

1

9

BLCM-102G

Natural

95,500 BTU

115

1

9

Propane

95,500 BTU

115

1

9

BLCM-62G

Natural

81,800 BTU

115

1

9

Propane

81,800 BTU

115

1

9

BLCM-202G

Natural

190,000 BTU

115

1

17

Propane

190,000 BTU

115

1

17

This manual is related to the following products: