Allied Telesis AT-MC602 User Manual
Page 46
![background image](/manuals/427649/46/background.png)
Configuration
46
Install
The Install mode enables a watchdog timer to monitor the link attempt
process. If the network extenders are not able to establish a link using
the parameters you set on the Provider unit within a reasonable amount
of time, a timeout will occur. After a timeout, the default configuration
parameters will be used to establish a link with the highest possible
speed. The default configuration parameters start at 0.94 Mbps
upstream and downstream with negotiation set from Low -> High.
Select the option that corresponds to your mode choice and click the
Apply button.
When the mode has been set, the AT-MC60x Configurator Done
message will appear, as displayed in Figure 26.
Figure 26 Done Message
When you have finished setting the mode on the Subscriber unit, click
the Close button on the bottom right of the AT-MC60x Configurator
menu to exit from the configuration software.