Troubleshooting

This section provides information on how to detect and resolve problems with
the SwitchBlade and its expansion options.

Other sources of useful troubleshooting information are:

www.alliedtelesis.com/support/software

.

The SwitchBlade Software Reference.

LEDs and What They Mean

The following tables outline how SwitchBlade LEDs report faults and
operational activities.

Switch Controller LEDs

The following LEDs will operate if the switch controller is receiving power.

Table 12: LEDs on the AT-SB4211 Switch Controller.

LED

State

Function

Power

Green

The switch controller is receiving power

Master

Amber

The switch controller is the master controller

Off

The switch controller is the slave controller

Fault

Red

The switch controller or management software
is malfunctioning

2 Flashes

1

A fan-tray fan has failed

3 Flashes

1

A PSU or PSU fan is malfunctioning

5 flashes

1

The fan tray has been removed for more than
20 seconds

6 Flashes

1

The switch’s internal temperature has
exceeded the alarm threshold

Slow flashing at
startup

The SDRAM (DIMM) has not been detected

Rapid flashing at
startup

The SDRAM (DIMM) is not compatible with the
switch

L/A

(Link/Activity)

Green

A 100 Mbps management port link is open

Amber

A 10 Mbps management port link is open

Flashing green

100 Mbps activity is occurring through the
management port

Flashing amber

10 Mbps activity is occurring through the
management port