1000base straight-through cable – Allied Telesis SwitchBlade 4000 Series Switch Hardware Reference User Manual
Page 44

44
SwitchBlade 4000 Series Switch
C613-03060-00 REV H
software test facility, to test 10/100BASE network and management ports.
Table 9 on page 44 lists the RJ-45 crossover wiring pin assignments.
1000BASE straight-through cable
For 1000BASE network connections, all four pairs are used and the cable is
wired in a straight-through configuration. This cable can also be used, in
conjunction with the software test facility, to test 1000BASE network ports.
Table 10 on page 44 lists the pin assignments.
Table 9: RJ-45 Pin assignments, two pair crossover cable.
End 1
End 2
1 (TX+)
3 (TX+)
2 (TX-)
6 (TX-)
3 (RX+)
1 (RX+)
6 (RX-)
2 (RX-)
Table 10: Pin assignments, 10/100/1000BASE-T RJ-45 four pair straight-through
cable
1
.
End 1
End 2
Pin
Pair
Pin
Pair
1
Pair 1+
1
Pair 1+
2
Pair 1-
2
Pair 1-
3
Pair 2+
3
Pair 2+
6
Pair 2-
6
Pair 2-
4
Pair 3+
4
Pair 3+
5
Pair 3-
5
Pair 3-
7
Pair 4+
7
Pair 4+
8
Pair 4-
8
Pair 4-