Cooling

Built-in fan

Monitoring of PSU fans for stalled or slow speed

LEDs

Three LEDs indicate power supply status (input, output, and fan status)

For a complete list of LEDs and their functions, see “LEDs and What
They Mean” on page 47

Electrical Specifications Per Chassis Type

Eight Slot Triple Feed AC Chassis (SB4108-00)

(100 to 240) V AC (50 to 60) Hz input

For a fully loaded chassis with eight line cards and a fan tray installed

Maximum continuous current draw for each active PSU, 4 A at 240 V,
8 A at 120 V (due to load sharing, redundant PSUs do not add to the
total continuous current drawn).

Maximum inrush current for each PSU (cold start), 75 A at 240 V, 37 A
at 120 V.

Eight Slot Dual Feed AC Chassis (SB4108-60)

200 V to 240 V AC (50 to 60) Hz input

For a fully loaded chassis with eight line cards and a fan tray installed

Maximum continuous current draw for each active power feed, 8Aat
240 V, 16 A at 120 V.

Maximum inrush current for each power feed (cold start), 150 A at
240 V, 75 A at 120 V.

Four Slot Dual Feed AC Chassis (SB4104-00)

100 V to 240 V AC (50 to 60) Hz input

For a fully loaded chassis with eight line cards and a fan tray installed

Maximum continuous current draw for each active power feed, 8A at
240 V, 16 A at 120 V.

Maximum inrush current for each PSU (cold start), 75 A at 240V, 37 A at
120V.

Eight Slot Dual Feed DC Chassis (SB4108-80)

Fully loaded chassis with four line cards and a fan tray installed

Maximum continuous current draw for each active power feed, 30A
within the rated input voltage range.

Maximum inrush current for each PSU (cold start), A within the rated
input voltage range.

Accepts positive or negative earthing (grounding)