AT-S95 Management Software Web Browser Interface User’s Guide
Defining RMON Alarms
The RMON Alarm Page contains fields for setting network alarms. Network alarms occur when a network
problem, or event, is detected. Rising and falling thresholds generate events.
To set RMON alarms:
1.
Click Statistics > RMON Alarm. The RMON Alarm Page opens:
Figure 161:RMON Alarm Page
The RMON Alarm Page contains the following fields:
•
Alarm Entry — Indicates a specific alarm.
•
Counter Name — Displays the selected MIB variable.
•
Interface — Displays interface for which RMON statistics are displayed. The possible field values are:
–
Port — Displays the RMON statistics for the selected port.
–
Trunk — Displays the RMON statistics for the selected trunk.
•
Counter Value — Displays the selected MIB variable value.
•
Sample Type — Defines the sampling method for the selected variable and comparing the value against the
thresholds. The possible field values are:
–
Delta — Subtracts the last sampled value from the current value. The difference in the values is
compared to the threshold.