Displaying and configuring ports – Allied Telesis AT-GS950/48 User Manual
Page 57

AT-GS950/48 Web Interface User Guide
57
Displaying and Configuring Ports
This procedure explains how to configure the ports on the
AT-GS950/48 switch using the Port Configuration Page. This page allows
you to view and configure the parameter settings of individual or all the
switch ports at one time.
To configure the ports, perform the following procedure:
1. From the main menu on the left side of the page, select Physical
Interface.
Figure 16. AT-GS950/48 Physical Interface Page
2. Adjust the port settings as needed. Not all parameters are adjustable.
The parameters are defined as follows:
Port - Specifies the port number. The All value indicates ports 1
through 48 on the AT-GS950/48 switch. You cannot change this
parameter.
Note
You can use the All row value in the Port column to set the Admin.
Status, Mode, Jumbo, Flow Ctrl, EAP Pass, and BPDU fields to
the same values for all ports at the same time. In the All row when
you select Ignore, Enable or Disable in one of these columns, it
applies to all of the AT-GS950/48 switch ports.
Trunk - This parameter indicates the trunk group number. A
number in this column indicates that the port has been added to a
trunk. This parameter can not be configured on this page,
However, for information about configuring a trunk, refer to Chapter
6, “Static Port Trunking” on page 93.
Type - Indicates the port type. On the AT-GS950/48, the port type
is 1000TX for 10/100/1000Base-T twisted-pair ports (1 through 44,
45R through 48R) and 100FX or 1000TX for the SFP ports (45