Campbell Scientific CS650 and CS655 Water Content Reflectometers User Manual
Page 14
CS650 and CS655 Water Content Reflectometers
CS650
CS655
Volumetric Water
Content using Topp
Equation (m
3
/m
3
)
Range:
5% to 50%
5% to 50%
Accuracy†:
±
3% VWC typical in
mineral soils where
solution EC ≤3 dS/m
±
3% VWC typical in
mineral soils where
solution EC ≤10 dS/m
Precision‡:
<0.05%
<0.05%
Electrical
Conductivity
Range Solution
EC:
0 to 3 dS/m
0 to 8 dS/m
Range Bulk EC: 0 to 3 dS/m
0 to 8 dS/m
Accuracy†:
±
(5% of reading +
0.05 dS/m)
±
(5% of reading +
0.05 dS/m)
Precision‡:
0.5% of BEC
0.5% of BEC
Temperature
Soil
Measurement
Range:
-10 to + 70°C
-10 to + 70°C
Operational
Range:
0 to + 70°C
0 to + 70°C
Accuracy†:
±
0.5°C for probe
body buried in soil
±
0.5°C for probe
body buried in soil
Precision‡:
±
0.02°C
±
0.02°C
Sensing Volume*:
7800 cm
3
3600 cm
3
*
Sensing Volume approximately 7.5 cm radius around each probe rod
and 4.5 cm beyond the end of the rods
†Accuracy specifications are based on laboratory measurements in a
series of solutions with dielectric permittivities ranging from 1 to 81
and solution electrical conductivities ranging from 0 to 3 dS/m.
‡Precision describes the repeatability of a measurement. It is
determined for the CS650 by taking repeated measurements in the
same material. The precision of the CS650 is better than 0.05 %
volumetric water content and 0.01 dS/m electrical conductivity.
6