beautypg.com

Xfer progress msgs - micrimage only, No micr' response - micrimage only, Micr scanning (enhanced reading - er) – MagTek MICRbase User Manual

Page 31: Ok – all rs232 models

background image

Section 5. Options For RS-232 Interface


6- no check# + short account

7- no check# + short account + amount present


4th digit

0- no errors

1- Chk #

2-

Account

3-

Account

+

Chk#

4- Transit

5-

Transit

+

Chk#

6-

Transit

+

Account

7- Transit + Account + Chk#


Extended Replies

-

MICRImage only


Check this box to receive errors as "?ddd" where ddd is a three-digit error code.

Xfer Progress Msgs - MICRImage only

Check this box to monitor the progress of network communications.

'No MICR' Response

-

MICRImage only

Check this box to receive "NO MICR" if there is no valid MICR line.

MICR Scanning (Enhanced Reading - ER)

This option is only available on MICRImage models manufactured after 9/01/2003.

If multi-scan is selected, the document is scanned three times: forward, reverse, and forward.
The MICR lines produced are compared character by character and mismatches replaced by '?'.
The resulting MICR line is the one that will be parsed, formatted, and transmitted.

Single

Single pass MICR read only.

Multi-scan, Match First Two

The first forward scan is compared to the reverse scan and the result is transmitted.

Multi-scan, Match Any Two

The three lines are compared in pairs and the first pair found that matches is transmitted.

Multi-scan, Match All

All three MICR lines are compared and the result transmitted.


OK – All RS232 Models

Keeps the current options and returns to the Main Screen. To save configuration changes to a
file, use the Save or Save As options from the File menu.

23