Section 4. Operation


To MICR:
swa<13>
From MICR:
SWA=00100110<13>

The <13> is the ASCII decimal value for carriage return.

Figure 4-2. Communicate With MICR


Display Space as <32> When the checkbox is not checked, a string of numbers received from
the MICR may be:

110 101 110 01

When the box is checked, the same numbers will read:


110<32>101<32>110<32><32>01

Clear clears the screen

Done returns to the Main Screen.

Communication Dialog All data sent and received from the MICR Reader will be displayed in
this box. The line “To MICR” will precede all data sent to the MICR Reader. The line “From
MICR” will precede all data received from the MICR Reader. The decimal values for
nonprintable ASCII characters will be displayed in angle brackets <>. When this box fills up,
the data will scroll up. The scroll bar on the right side may be used to display data not visible on
the screen.