beautypg.com

Control characters and micr data, Send data after error – all rs232 models, Send status – all rs232 models – MagTek MICRbase User Manual

Page 28

background image

MICRbase, Setup Program for MICR Readers


Check), and appends it to the data message. Also, if a (hex 15) character is received in
this mode, the MICR Reader will resend the last message.

Control Characters and MICR Data

The Control Characters and hex values are as follows:

OPTION CONTROL

CHARACTER

HEX VALUE

Leading

02

Leading

1B

Trailing

03

Trailing

0D

Trailing

0A

Control Characters may be added to the MICR data message. The characters are always in the
following locations:

data


For example, if the and boxes are checked, the message from the MICR Reader
will look like this:

MICR Data: data

Note

When Com Mode is used, the individual control characters are not
available.


Send Data After Error –
All RS232 Models

This box specifies whether the MICR Reader will return data to the host after a read error. If the
box is checked and the unit reads a check with an error, the MICR Reader will send the data back
to the host. If the box is not checked and the MICR Reader finds an error, it will discard the data
and nothing will be sent. The error conditions are in the table below.

Send Status – All RS232 Models

This box makes the MICR Reader append a two-digit error/status code to the end of the MICR
data. For most formats the error/status code will always be preceded by a forward slash (/).

For example, if a Canadian check (code 08) is read and had no errors, and the MICR data is
“1234567890”, then the message from the MICR Plus will look like this:

MICR Data: 1234567890/08