14 Troubleshooting

Although the DTRX3 receiver is characterized by a great ease of use, sometimes troubles may occur,

especially during the installation and configuration phases or using the unit.

PROBLEM

PROBABLE CAUSE

REMEDY

Led LD1 is off

• No power supplied to the unit
• The fuse is blown

• Check the power cable
• Replace the F5 fuse

Led LD1 is on but the
commands are not
executed

• Wrong configuration of the

reception

• Wrong

connection

• Wrong DTRX3 identification
• The unit is blocked
• Wrong communication speed or

protocol

• In case of RS485 mode, check if the load

is inserted/not inserted with JP5 jumper. In
case of Current Loop mode, verify that the
JP2 and JP3 jumper are on CL position.

• Check the connecting cables
• Check the identification number of DTRX3

(SW1-SW2-SW3)

• Press the reset key P1 or turn off the

power supply

• Check the setting of dip 1,2 and 8 of SW4

and of dip 1 of SW6

The positioning device
does not work

• Wrong power supplied to the

positioning device

• Make sure that the supply voltage of the

positioning device corresponds to the one
supplied by the receiver

The lens does not work

• Wrong lens voltage

• Check the adjustment of the TR1 trimmer

The alarms does not
work

• Wrong configuration of alarms

dip

• Control the setting of Dip3, 4 and 5 of

SW4

In a cascade connection,
the units which follow do
not receive the user’s
commands

• Wrong

connection

• Wrong configuration of the

reception

• Dip switch wrong configuration

• Check the connecting cables
• In case of RS485 mode, check if the load

is inserted/not inserted with JP6 jumper. In
case of Current Loop mode, verify that the
JP2 and JP3 jumper are on CL position.

• Control the address setting of the non-

functioning units