6.4 Type of lenses used

WARNING! An inaccurate setup of this parameters can cause damages to the lenses!


The DTRX3 receiver can control both polarity inversion lenses and common wire lenses. In case of common
wire lenses connect the common wire to FOCUS.

6.5 Setting the protocol and the communication speed

WARNING! An inaccurate protocol and/or communication speed selection can cause damages to the

receiver.

The DTRX3 receiver can be used in digital transmission systems and it can communicate with a speed from
300 to 38400 baud, depending on the used protocol.

Dip switch: switches 1, 2 and 8 of SW4 and 1 of SW6.
Settings:

Protocol - Baud rate

SW6

SW4

Dip 1

Dip 1

Dip 2

Dip 8

Videotec - 300 baud

OFF ON

OFF

ON

Videotec - 1200 baud

OFF OFF ON

ON

Videotec - 9600 baud*

OFF OFF

OFF

ON

Videotec - 19200 baud

OFF ON ON

ON


MACRO - 1200 baud

OFF OFF ON

OFF

MACRO - 9600 baud

OFF OFF

OFF

OFF

MACRO - 19200 baud

OFF ON ON

OFF

MACRO - 38400 baud

OFF ON

OFF

OFF

Pelco D - 2400 baud

ON OFF

OFF

**

Pelco D - 4800 baud

ON ON

OFF

**

Pelco D - 9600 baud

ON OFF

ON

**

Pelco D - 19200 baud

ON ON

ON

**

NOTES:
* Default

setting

**

Switch setting is indifferent; ON or OFF