4 type of lenses used, 5 setting the protocol and the communication speed – Videotec DTRX3 User Manual
Page 39
Page
9
MNVCDTRX301_0850
6.4 Type of lenses used
WARNING! An inaccurate setup of this parameters can cause damages to the lenses!
The DTRX3 receiver can control both polarity inversion lenses and common wire lenses. In case of common
wire lenses connect the common wire to FOCUS.
6.5 Setting the protocol and the communication speed
WARNING! An inaccurate protocol and/or communication speed selection can cause damages to the
receiver.
The DTRX3 receiver can be used in digital transmission systems and it can communicate with a speed from
300 to 38400 baud, depending on the used protocol.
Dip switch: switches 1, 2 and 8 of SW4 and 1 of SW6.
Settings:
Protocol - Baud rate
SW6
SW4
Dip 1
Dip 1
Dip 2
Dip 8
Videotec - 300 baud
OFF ON
OFF
ON
Videotec - 1200 baud
OFF OFF ON
ON
Videotec - 9600 baud*
OFF OFF
OFF
ON
Videotec - 19200 baud
OFF ON ON
ON
MACRO - 1200 baud
OFF OFF ON
OFF
MACRO - 9600 baud
OFF OFF
OFF
OFF
MACRO - 19200 baud
OFF ON ON
OFF
MACRO - 38400 baud
OFF ON
OFF
OFF
Pelco D - 2400 baud
ON OFF
OFF
**
Pelco D - 4800 baud
ON ON
OFF
**
Pelco D - 9600 baud
ON OFF
ON
**
Pelco D - 19200 baud
ON ON
ON
**
NOTES:
* Default
setting
**
Switch setting is indifferent; ON or OFF