beautypg.com

Table 2-2 lun mapping options, To display the new security settings, type, Figure 2-12 security settings screen – APC SGI 15000 RAID User Manual

Page 40

background image

Controller Installation

26

007-5510-002

10. Enter a new unique LUN mapping for this user. Options are shown in Table 2–2 on page 26.

11. Connect user 2 and repeat steps 2--10 to specify the host port zoning and LUN mappings with the

following changes:

- For active host port (step 6), enter port 2 only.

- For LUN mapping:

External LUN 0 is mapping to internal LUN: R1

External LUN 1 is mapping to internal LUN: 1

External LUN 2 is mapping to internal LUN: q

NOTE : In this scheme, users 1 and 2 have their own custom LUN identification scheme. The internal

LUN 1 that is shared by the users needs to be managed by SAN management software.
The individual dedicated LUN appears to the user as local storage and does not require
external management software.

12. To display the new security settings, type:

user

.

Figure 2–12 shows a finished sample.

Figure 2–12

Security Settings Screen

Table 2–2

LUN Mapping Options.

Option

Description

G.1

GROUP.LUN number

P

place-holder

R

Read-Only. Place before the GROUP.LUN

N

Clear current assignment

No Change

E

EXIT

?

Display detailed help text.

15000 [1]: user

LUN Zoning

-------------------------------------------------------------------------------

User

210000E08B057383

000 client1

World Wide Name

1 4

User auditing is enabled.

External LUN, Internal LUN

Ports

1

2

R000,001

001,0

210000E08B028233

128 client2

2

R000,001 001,1