Drive Enclosure Troubleshooting

007-5510-002

121

8.4 Audible Alarm

When the Audible Alarm sounds, use the appropriate SES CLI command.

8.4.1

Top Cover Open

The Audible Alarm sounds anytime the top cover is open. The alarm mutes automatically once the cover
is closed.

8.4.2

SES Command

The Audible Alarm can be set through SES communication. When set in this manner, the alarm remains
on until any one of the following conditions is met:

• Enclosure is power cycled.
• Alarm is turned off through SES command.

8.5 Troubleshooting

The following sections describe common problems (and possible solutions) you might encounter with
your drive enclosure system.

8.5.1

Thermal Control

The drive enclosure uses extensive thermal monitoring and takes a number of actions to ensure
component temperatures are kept low and also to minimize acoustic noise. Air flow is from the front,
over the drive section, through the midplane, through the I/O modules to rear of the enclosure.

Cover Open

AMBER

Enclosure cover
is open

OFF-both cover pieces securely
closed and latched in place.
ON-either of the cover pieces is
NOT securely closed and
latched in place

DEM Fault

AMBER

DEM fault

OFF-all DEMs operating
correctly.
ON-at least one DEM has failed;
service action required

Drive Fault

AMBER

Drive fault

ON-one or more HDDs are
faulted. SES must determine
exact HDD.
OFF-no detectable drive faults

Table 8–5

Display Panel LEDs

ICON

LABEL

COLOR

Definition

Normal Behavior