beautypg.com

5 dc output pcm, 6 pcm safety and emc compliance, 7 power cord – APC SGI 15000 RAID User Manual

Page 121: 7 environment, Dc output pcm, Pcm safety and emc compliance, Power cord

background image

Drive Enclosure

007-5510-002

107

5.6.5

DC OUTPUT PCM

5.6.6

PCM Safety and EMC Compliance

5.6.7

Power Cord

(minimum requirements)

Note

Power cord is not included in the standard drive enclosure package.

5.7 Environment

The enclosure and all of its sub-components are compliant to the European Union RoHS (Restriction of
Hazardous Substances) Directive (Directive 2002/95/EC) with no exceptions or exemptions.

Output Parameter

3.3 VDC Output 5 VDC Output 12 VDC Output

Normal Voltage

3.3 VDC

5.10 VDC

12.10 VDC

Full Load

5.0A

55.0A

120.0A

Peak Load for 1 Second

5.0A

65.0A

130.0A

Minimum Load (A)

0.0A

0.0A

0.0A

Safety Compliance

UL 60950

IEC 60950

EN 60950

EMC Compliance

CFR47 Part 15B Class A

EN55022

EN55024

Cord Type

SV or SVT, 18 AWG minimum, 3 conductor

Plug

250V, 10A

Socket

IEC 320 C-14, 250V, 15A