emc-3 Controller Module
User Guide – Rev A
Bank_2_Rev_DYCY
0
100
DYCY for Reverse Fan
Operation
Bank_3_Off_DYCY
0
Start - 1
DYCY to ensure fan is Off
Bank_3_Start_DYCY
0
Max - 1
DYCY for Minimum Fan Speed
Bank_3_Max_DYCY
Start + 1 100
DYCY for Maximum Fan Speed
Bank_3_Rev_DYCY
0
100
DYCY for Reverse Fan
Operation
Startup_Delay_Seconds
0
300
Delay from Power on until the
unit will operate fans
Minimum_Fan_Cycle_Seconds
0
300
Minimum time fans can run on
each bank
Bank_1_Fans_Idle_Enable
0
65535
(False = 0, 1 - 65535 = True)
Sets fans to run at min speed
when system is enabled
Bank_2_Fans_Idle_Enable
0
65535
(False = 0, 1 - 65535 = True)
Sets fans to run at min speed
when system is enabled
Bank_3_Fans_Idle_Enable
0
65535
(False = 0, 1 - 65535 = True)
Sets fans to run at min speed
when system is enabled
Engine_Minimum_RPM
0
2500
Minimum RPM for system
enable when EEC1 message is
enabled
HCT_Status_Msg_Enable
0
65535
(False = 0, 1 - 65535 = True)
Sets fans to run at min speed
when system is enabled
Reverse_Dwell_Seconds
0
30
Dwell before fans go to the
Reverse DYCY
Fire_Input_Enable
0
2
(False = 0, 1 = Active Low, 2 =
Active High) Fire Input Enabled
Fan_DG_Input_Enable
0
65535
(False = 0, 1 = Active Low, 2 =
Active High) True = DG Inputs
Enabled
Bank_1_Control_1
0
7
Assignment for control input
Bank_1_Control_2
0
7
Assignment for control input
Bank_1_Control_3
0
7
Assignment for control input
Bank_2_Control_1
0
7
Assignment for control input
Bank_2_Control_2
0
7
Assignment for control input
Bank_2_Control_3
0
7
Assignment for control input