emc-3 Controller Module
User Guide – Rev A
Appendix B, Status LED Alarm Codes
Code
Description
Controller Action
1
DG Input Active
Indication Only (Load absorbed by the
system)
2
Over Temp Active
Indication Only (Has Fans at Max Already)
3
CAN Bus Error
All Fans Max Speed until clear
4
Fire Input Active
All Fans Hard Stop (Bank_n_Off_DYCY)
5
Reverse Mode
Active Indication
only
6
Ignition Input Error
Indication only
7
Auto dB Test Active Indication only
8
Manual Mode Active Indication only
9
Thermistor Input
Error
All Fans Max Speed until clear