beautypg.com

Emc-3 controller module, Sae j1939 can messages – High Country Tek emc-3 User Manual

Page 17

background image

Page 17 of 39

emc-3 Controller Module

User Guide – Rev A

SAE J1939 CAN Messages


All J1939 CAN messages for the EMC-3 can be either enabled or disabled
except the FD (fan drive)

State message. The FD State is always transmitted

when the system is enabled. The HCT Status message will be transmitted when
it is enabled in the EE-Memory and the system is enabled.

Setting the Engine Minimum RPM to a value that is greater than 0 will enable the
EEC1 message. All other messages are enabled by entering their corresponding
control number in one of the nine Bank Control fields. All unused messages are
automatically disabled in software to prevent false timeout errors.

Current messages and their control selection codes are as follows, reference
SAE J1939-71 for specific information about the following messages and SPNs
for the emc-3;

Received Messages

Name PGN

Description

SPN / Measurement

Control

Selection

Code

CM1 57344

Percent Requested
Fan Speed

SPN 986, Requested
Fan Speed

1

CM1 57599

Percent Requested
Fan Speed

SPN 986, Requested
Fan Speed

1

ET1 65262

Engine

Temperature

1

SPN 110, Engine
Temperature 2

IC1

65270 Intake Conditions 1

SPN 105, Manifold
Temperature 3

TF 65272

Transmission

Fluids

SPN 177,
Transmission Oil
Temperature 4

EEC1 61444

Electronic Engine
Control 1

SPN 190, Engine
Speed N/A


Send Messages

Name PGN

Description

FD

65213 SPN 975 & SPN 977, Fan Drive State

HCT
Status 65280

Status

of Module Flags & I/O