Baud, 9600 data, 7par – Red Lion PAXCK User Manual
Page 27: Odd addr, 00 abbr, Yes opt, T-dsp, Yes c-dsp, No rtc-d, No rtc-t

27
7-SrL
Serial Communication Parameters
DISPLAY
PARAMETER
FACTORY
SETTING
USER SETTING
bAUd
BAUD RATE
9600
dAtA
DATA BITS
7
PAr
PARITY BIT
Odd
Addr
METER UNIT ADDRESS
00
Abbr
ABBREVIATED PRINTING
NO
REAL-TIME CLOCK PRINT FORMAT
YES
OPt
PRINT OPTIONS
t-dSP
TIMER DISPLAY
YES
C-dSP
CYCLE COUNTER DISPLAY
NO
rtC-d
RTC DATE DISPLAY
NO
rtC-t
RTC TIME DISPLAY
NO
spNt
SETPOINT VALUES
NO
SPNtOF
SETPOINT OFF/ TIME-OUT VALUES
NO
PARAMETER
USER SETTING
FACTORY
SETTING
dSP-t
12-59p
dSP-d
DATE DISPLAY FORMAT
12-31
SyNC
Ch-dSt
sLAVE
N0
OFFSEt
CAL
00
TIME DISPLAY FORMAT
DISPLAY
AUTO TIME CHANGE FOR D.S.T.
SYNCHRONIZATION UNIT TYPE
CALIBRATE REAL-TIME CLOCK
RTC CALIBRATION OFFSET VALUE
9-fCS
Factory Service Parameters
DISPLAY
DISPLAY INTENSITY LEVEL
3
d-LEV
FACTORY
SETTING
USER SETTING
PARAMETER
Shaded areas are model dependent.
Shaded areas are model dependent.
8-rtC
Real-Time Clock Parameters
OUt-n
tOUt-n
SPOF-n
OFF-n
SP-n
ON-n
ASM-n
ACt-n
DISPLAY
NOr
NOr
NOr
NOr
SETPOINT ANNUNCIATOR
POWER-UP STATE
NO
NO
NO
NO
OUTPUT RESET W/DISPLAY RESET
NO
NO
NO
NO
TIMER/COUNTER AUTO RESET
NOr
NOr
NOr
NOr
OUTPUT LOGIC
VALUE
VALUE
VALUE
000100
000100
000100
VALUE
000100
VALUE
VALUE
000100
000100
000100
SETPOINT OFF VALUE (B)*
VALUE
SETPOINT OFF (B)*
TIME-OUT VALUE (B)*
TIME-OUT VALUE (A)
000100
SETPOINT OFF VALUE (A)
VALUE
SETPOINT OFF (A)
LAtCH
LAtCH
LAtCH
VALUE
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
VALUE
NONE
SP-4
USER SETTING
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
NONE
SP-3
LAtCH
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
VALUE
NO
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
000000
000000
VALUE
VALUE
SETPOINT ON (B)*
NONE
SP-2
SETPOINT ACTION
USER SETTING
NO
TIMER STOP
Mon-Fri
DAILY OFF OCCURRENCE (B)*
Mon-Fri
DAILY OFF OCCURRENCE (A)
Mon-Fri
DAILY ON OCCURRENCE (B)*
Mon-Fri
DAILY ON OCCURRENCE (A)
000000
SETPOINT ON VALUE (B)*
000000
SETPOINT ON VALUE (A)
VALUE
SETPOINT ON (A)
NONE
SETPOINT ASSIGNMENT
SP-1
6-SPt
Setpoint (Alarm) Parameters
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
PARAMETER
PAXCK Application
A big application request has always been for
Real-Time Clocks to display time throughout the
plant. The challenge has been to keep all the
various clock locations synchronized with the
right time. With the new PAXCK Timer/Real-
Time Clock this problem is history. The clocks can
be provided in three different sizes, the PAXCK
(0.56 inch LEDs), the LPAXCK (1.5 inch LEDs),
or the EPAX (4 inch LEDs). You can mix and
match any number of the two versions, up to a
maximum of 32 units. Simply select one of the
units in the system as the host and the balance are
programmed as slaves. The host will send out a
synchronization pulse every hour to correct the
time on any clock unit wired in the system.
Real-Time Clock Synchronization Network
* See Module 2, Exchanging Parameter Lists, for details on programming this value.