LGM APPLICATION
A process performs five different procedures to a piece of raw stock at five different locations. The Legend series LGM with six presets
and six solid state outputs is used for this application.
The raw stock comes in ten foot sections and requires five various operations to be performed at 9.00", 23.00", 72.00", 83.00", & 111.00".
A rotary pulse generator (RPGB) with a 600 pulse per revolution (PPR) quadrature output is coupled to a 1 foot circumference wheel. A
quadrature sensor is specified because the stock must be reversed after stations #1 and #4. This allows the Legend to keep track of true position.
The Legend is set to the quadrature X2 mode
which increases the pulses to 1200 PPR. This gives a
measurement resolution of 1/100 of an inch. The five
Presets are programmed with the proper values and
the solid state outputs control pilot relays that control
the actuators. As the material passes each station, a
signal is sent to the proper equipment and the process
is performed. Also, the outputs are programmed so
that if a power outage occurs they will save the state
that they were in at power down.
The sixth output is assigned to rate so that if the
rate drops below a predetermined value the output
will activate a warning indicator.
5 6 7 8 9 10
1 2 3 4
5
1 2 3 4
9
8
7
6
11
10
INPUT
A
INPUT
B
COMM.
INHIBI
T
USR.INP.
1
USR.INP.
2
USR.INP.
3
TX/RX (+
)
TX/RX (-)
TX EN
.
RS-485
AC PW
R
(SEE SIDE
LABEL
)
+12VDC
(IN/OUT
)
COMM.
COMM.
WHIT
E
GR
N
RE
D
BL
K
SHIELD
ACTUATOR
#1
#2
ACTUATOR
#3
ACTUATOR
#4
ACTUATOR
#5
ACTUATOR
01-SN
K
02-SN
K
03-SN
K
04-SN
K
05-SN
K
06-SN
K
FROM
RELAY #1
FROM
RELAY #2
FROM
RELAY #3
FROM
RELAY #4
FROM
RELAY #5
TO
RELAY #1
RELAY #2
TO
RELAY #3
TO
RELAY #4
TO
RELAY #5
TO
TO
WARNING
INDICATOR
TO DC
POWER
SOURCE
-
+
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
OPTION
w/RELAY BOARD
LGS
Single Preset Legend w/Yel-Grn Backlighting
No
LGS00001
Single Preset Legend w/Yel-Grn Backlighting
Yes
LGS00000
Single Preset Legend w/Red Backlighting
No
LGS00101
Single Preset Legend w/Red Backlighting
Yes
LGS00100
LGD
No
LGD00001
Dual Preset Legend w/Yel-Grn Backlighting
Yes
LGD00000
No
LGD00101
Dual Preset Legend w/Red Backlighting
Yes
LGD00100
LGB
Four Preset Batch Legend w/Yel-Grn Backlighting
Yes
LGB00000
Four Preset Batch Legend w/Red Backlighting
Yes
LGB00100
LGM
Multi Preset (6) Legend w/Yel-Grn Backlighting
N/A
LGM00001
Multi Preset (6) Legend w/Red Backlighting
N/A
LGM00101
_
Single Relay Board
N/A
RLYLG001
_
Dual Relay Board
N/A
RLYLG002
Dual Preset Legend w/Yel-Grn Backlighting
Dual Preset Legend w/Red Backlighting
PART NUMBERS
115/230 VAC
& +12 VDC