Page 3

background image

PROGRAMMING

The Legend Series provides an easy to use, menu driven programming

interface. The English prompts, the front panel keypad, and the flashing display

aids the operator during programming. In the normal run mode, the main

display loop allows the user to scroll through the four programmable indication

displays, using the direction keys. From the main loop, presets and scale factors

can be accessed directly for changing parameters. All other parameters are

accessed through the programming loop. In the programming loop, parameters

can be viewed or changed and the operator can exit anywhere in the loop.

Shown to the side is part of the main display loop and part of the programming

loop of a Dual Preset Legend (LGD) unit. Also shown are four different views

of the indication displays.

PROGRAMMABLE FUNCTIONS

PRESET(S)

Ranges from -99999 to 999999

Counter Load ranges from -99999 to 999999

SCALE FACTORS (RATE & COUNT)

Range from 0.0001 to 5.9999

COUNT SCALE MULTIPLIER

Multiplies the contents of the 9-digit internal counter or the 11-digit internal

totalizer by a factor of 1, 0.1, 0.01 or 0.001 to view the desired number of

significant digits on the 6-digit Counter display or the 8-digit Totalizer display.
DECIMAL POINT

Separate decimal point location for Count and Rate displays.

0

0.0

0.00

0.000

0.0000

0.00000

RATE SCALE MULTIPLIERS

Multiplies the contents of the actual internal rate, pulses per second (PPS), by

a factor of 0.01, 0.1, 1, 10, 100, or 1000 to view the desired number of

significant digits on the 6-digit Rate display. The desired time units that the rate

is to be displayed, can also be programmed as per Second (x1), per Minute

(x60), or per Hour (x3600).
UPDATE TIME

The Rate Minimum/Maximum Update Times range from 0.1 to 99.9 seconds

which provides averaging capability for non-consistent pulse spacing.

COUNTING MODES

Count with Direction

Count with Direction (X2)

Quadrature

Quadrature (X2)

Quadrature (X4)

2-Input Anti-coincidence Add/Add

2-Input Anti-coincidence Add/Subtract

A separate Inhibit input, is available for all count modes.

RESET MODES

Manual Reset

Automatic Reset at Preset

Reset at Beginning Of Output 1

Reset at End Of Timed Output 1

Reset at Beginning Of Output 2

Reset at End Of Timed Output 2

Reset at Beginning Of Output 1 or Output 2

Reset at End Of Timed Output 1 or Output 2
MODEL LGB ONLY

Reset at Beginning Of Output 3

Reset at End Of Timed Output 3

Reset at Beginning Of Output 4

Reset at End Of Timed Output 4

Reset at Beginning Of Output 3 or Output 4

Reset at End Of Timed Output 3 or Output 4

RESET ACTION

Reset to Zero: Output activates when the count equals the preset value. Count

display value returns to zero when reset.

Reset to Preset: Output activates when the count equals zero. Count display

value returns to preset value when reset.

Reset to Counter Load: Output activates when count equals the preset value.

Count display value returns to counter load value when reset.

USER INPUTS

There are three external user inputs and two front panel Function keys that

are programmable. When activated each User Input can be programmed to

perform one of the following functions:
Maintained Reset or Momentary Reset:

Can reset Rate, Peak, Valley, Process*, Batch*, Total*, or Count* display values

and/or any output associated with that display.

*Models with the available display.

3

ENT

RST

F2

ESC

SEL

F1

F1

SEL

ESC

F2

RST

ENT

29637

F1

SEL

ESC

F2

RST

ENT

ENT

RST

F2

ESC

SEL

F1

PRS

PRS

PRS

PRS

PEAK

C 816352

R 20406

RATE

20406

COUNT
816352

4

3

2

1

MAIN DISPLAY LOOP

>

>

>

>

>

>

>

>

PRS

S.F.'S

PROGRAM

ESC

<

ESC

<

<

ESC

>

SEL

>

SEL

>

>

>

>>

>

ENT

ENT

>

>

>

SEL

>

SEL

OPTIONS

PROGRAM

PRINT OP

PROGRAM

COM.PORT

PROGRAM

DISPLAY

PROGRAM

OUTPUTS

PROGRAM

USER

PROGRAM

COUNTER

PROGRAM

RATE

PROGRAM

SCALING

PROGRAM

816352

COUNT

PROGRAM
MODE

SCALE
FACTORS

VALLEY

9124

PEAK

29637

RATE

PROGRAM

PRESETS

AND

COUNTER

LOAD

VALUE

SEL

>

SEL

>

SEL

>

SEL

>

SEL

>

SEL

>

SEL

>

*

>

SEL

>

PROGRAMMING LOOP

... DOTTED LINE:

MAIN DISPLAY LOOP

--DASHED LINE:

1-4 - THE FOUR INDICATION DISPLAYS

PROGRAM DISABLE FUNCTION

* - CAN BE DISABLED USING THE

20406

*