Troubleshooting, Problem situations, Chapter 6 – Vaisala WMT700 User Manual
Page 75

Chapter 6 ___________________________________________________________ Troubleshooting
VAISALA _______________________________________________________________________ 73
CHAPTER 6
TROUBLESHOOTING
This chapter describes common problems, their probable causes and
remedies, and provides contact information for technical support.
Problem Situations
Table 23 below lists some problems situations that can occur during or
after retrofit installation. For general troubleshooting instructions, refer to
Vaisala WINDCAP
®
Ultrasonic Wind Sensor Series WMT700 User's
Guide.
Table 23
Some Problem Situations and Their Remedies
Problem Probable
Cause
Remedy
Retrofit installation of
WMT700 is not possible.
You do not have the
correct mounting kit for
the retrofit installation.
Check that you are using
the FIX30 or FIX60
mounting kit and the
correct mounting
adapter.
If you do not have the
correct mounting kit,
contact Vaisala technical
support.
WMT700 does not work
properly after retrofit
installation.
Incorrect cables were
used in the retrofit
installation.
Check that you have
used cables listed in
Check List for
Connection Cables on
page 24.
If you do not have the
correct cables, contact
Vaisala technical
support.
Connection to WMT700
is lost.
The power supply is not
sufficient, especially if
you are using a heated
version of WMT700.
Check that the power
supply matches the
requirements in section
Powering on page 30.