Sdi-12 data messages, Ws425 a/b sdi-12 message for c and m command, Missing readings – Vaisala WMT700 User Manual
Page 72

TECHNICAL REFERENCE___________________________________________________________
70 __________________________________________________________________ M211097EN-C
SDI-12 Data Messages
When SDI-12 profile is selected, the data message sent by WMT700
depends on the command that you use before fetching the data with aD0!
command.
WS425 A/B SDI-12 Message for C and M Command
When you have given the commands aC! or aM! followed by aD0!, the
response is the following:
a
where
a
=
The single-digit WMT700 address that corresponds
to the first character of the address value.
=
Polar wind speed in selected units
Format: +(ss)s.s
=
Polar wind direction in degrees
Format: +(dd)d.d
=
x component of wind speed in selected units
Format: ±(ss)s.s
=
y component of wind speed in selected units
Format: ±(ss)s.s
=
Static speed of sound in miles per hour
Format: ±(ss)s.s
=
Terminates the response.
The above are measurement data fields.
Missing Readings
If data is missing due to a measurement problem (for example, blocked
paths between transducers), the measurement data is replaced with 999.9.
Example of the command and response when data is missing:
7D0!
7+999.9+999.9+999.9+999.9+999.9