Vaisala WMT700 User Manual
Page 54

TECHNICAL REFERENCE___________________________________________________________
52 __________________________________________________________________ M211097EN-C
Table 15
Configurable Parameters for WS425 A/B NMEA
Extended Profile
Parameter Default
Value
Profile-specific Allowed
Values
Description
address
1
String with 1 character
Address for WMT700.
autoInt
1
0.25 ... 1000
Resolution: 0.25
Automatic message interval in seconds.
Do not select a message interval that is
shorter than the time it takes to send a
data message.
autoPort 1
1=COM1
port
2=COM2 port
Serial port to which WMT700 sends
automatic data messages.
autoSend
0
0 = automatic messages
disabled
19 = NMEA automatic
data message
Automatic data message number. Selects
the data message format for automatic
messages.
com1_protocol
com2_protocol
(depending on
the port used for
operating
WMT700)
0
5 = WS425 A/B NMEA
Extended
Profile for serial ports COM1 and COM2.
wndAvg
1
0.25 … 3600
Resolution: 0.25
Averaging time for wind measurement in
seconds.
wndOrientation
0
0 = array facing up
1 = array facing down
Orientation of the array of WMT700.
wndUnit
0
0 = meters per second
1 = miles per hour
2 = kilometers per hour
3 = knots
Wind speed unit.
wndVector
1
0 = scalar averaging
Wind averaging method.
To start continuous measurement, use the START command. You can
stop the measurement with the STOP command. For instructions, refer to
Vaisala WINDCAP
®
Ultrasonic Wind Sensor Series WMT700 User's
Guide.