Missing readings, Ws425 a/b wat11 profile, Configurable parameters – Vaisala WMT700 User Manual
Page 60
TECHNICAL REFERENCE___________________________________________________________
58 __________________________________________________________________ M211097EN-C
Interpretation of the example message:
-
┐
02H (
- Sensor
ID:
W
- Averaging in seconds: 5
- Sensor status: P = pass
- Wind direction: 120
- Wind speed: 0013
- . (dot character)
- Wind speed unit: T = meters per second
- Checksum (most significant digit): D
- Checksum (least significant digit): E
-
└
03H (
Missing Readings
If data is missing due to a measurement problem, the WS425 A/B ASCII
message reports 999.9 for wind speed.
WS425 A/B WAT11 Profile
Configurable Parameters
Table 20 below lists the configurable parameters and their allowed and
default values for the WS425 A/B WAT11 profile.
Table 20
Configurable Parameters for WS425 A/B WAT11
Profile
Parameter Default
Value
Profile-specific Allowed
Values
Description
com1_protocol
com2_protocol
(depending on
the port used
for operating
WMT700)
0
6 = WS425 A/B WAT11
Profile for serial ports COM1 and COM2.
To start continuous measurement, use the START command. You can
stop the measurement with the STOP command. For instructions, refer to
Vaisala WINDCAP
®
Ultrasonic Wind Sensor Series WMT700 User's
Guide.