beautypg.com

Product overview, Introduction to dpt146, Basic features and options – Vaisala DPT146 User Manual

Page 14: Chapter 2, Table 3, Output parameters of dpt146, Chapter 2, product overview

background image

User's Guide _______________________________________________________________________

12 ___________________________________________________________________ M211372EN-D

CHAPTER 2

PRODUCT OVERVIEW

This chapter introduces the features, advantages, and product options.

Introduction to DPT146

Vaisala Dewpoint and Pressure Transmitter DPT146 for Compressed Air

combines online measurement of dewpoint and pressure. The dewpoint

measurement is continuously pressure compensated using the measured

pressure. Temperature output is also available if the transmitter has been

ordered with serial line output.

DPT146 also calculates two other parameters, ppm moisture by volume

and dewpoint in atmospheric pressure. The transmitter’s compact size

makes it well suited for integration into OEM systems.

Table 3

Output Parameters of DPT146

Parameter

Abbreviation Metric Unit Non-Metric

Unit

Dewpoint/frost point temperature* Tdf

ºC

ºF

Dewpoint/frost point temperature*,

converted to atmospheric pressure

Tdfatm

ºC

ºF

ppm moisture, by volume

H20

ppm

ppm

Pressure, absolute

P

bara

psia

Temperature**

T

ºC

ºF

* When the dewpoint is below 0 °C, the transmitter outputs frost point for T

d

** Available if RS-485 only output is selected

Basic Features and Options

- Utilizes the Vaisala MPS1 multiparameter sensor with Vaisala’s

BAROCAP® and DRYCAP® technologies.

- Measurement ranges of measured parameters:

- Dewpoint

-60 ... +30 °C (-76 ... +86 °F) T

d

- Pressure, absolute 1 ... 12 bar (14.5 ... 174 psi)
- Temperature -40 ... +80 °C (-40 ... +176 °F)

- Two analog output channels, selectable from 0 … 20 mA / 4 ... 20 mA

and 0 … 5 V / 0 … 10 V.

- Digital output: non-isolated RS-485.