Disassemble the Radiation Shield — Temperature/Humidity
Station

Note:

We recommend using a workbench or table to perform the following procedures.

1. Place the Temperature/

Humidity Station on a
level surface.

2. Loosen the three

mounting screws that
hold the mounting
bracket and the
radiation shield
together.

3. Separate the radiation

shield plates to locate
the Temperature/
Humidity sensor in the
plating. See “Remove
the Previous
Temperature/Humidity
Sensor” b
elow for
instructions on
removing the previous sensor.

Remove the Previous Temperature/Humidity Sensor
1. Locate the Temperature/Humidity sensor on the second to bottom plate in

the radiation shield plating stack.

2. Remove the three screws and flat washer securing the Temperature/

Humidity sensor to the radiation plating.

Mounting
Bracket

Radiation
Shield
Assembly

Lock Washers

Flat Washers

4" Screws

Cable Clamp

Temperature/Humidity
Sensor