Table 3-5. main menu summary - (cont) – Boonton 4530 Peak Power Meter User Manual User Manual
Page 67

3-45
Boonton Electronics
Chapter 3
4530 Series RF Power Meter
Operation
FrDepOfst . . . . . . . . . . . . . . . . . . . . Freq Dependent Offset Submenu
Ofst Src . . . . . . . . . . . . . . . . . . . . . Select Offset Table
Modify-A . . . . . . . . . . . . . . . . . . . . . View/edit Freq Dep Offset Table A
Modify-B . . . . . . . . . . . . . . . . . . . . . View/edit Freq Dep Offset Table B
Snsr Data . . . . . . . . . . . . . . . . . . . . Sensor Data Submenu
SensrInfo . . . . . . . . . . . . . . . . . . . . View general sensor information
FastTable . . . . . . . . . . . . . . . . . . . . View high-bw calfactor table (Peak Sensors only)
SlowTable . . . . . . . . . . . . . . . . . . . . View low-bw calfactor table (Peak Sensors only)
FreqTable . . . . . . . . . . . . . . . . . . . . View frequency calfactor table (CW Sensors only)
GainConst . . . . . . . . . . . . . . . . . . . View linearity calibration table (CW Sensors only)
TempComp . . . . . . . . . . . . . . . . . . . Select temperature compensation mode
Load Ref . . . . . . . . . . . . . . . . . . . . . Load Reference level from currently measured power
Ref Off
. . . . . . . . . . . . . . . . . . . . . Disable Reference
Enter Ref . . . . . . . . . . . . . . . . . . . . Enter Reference level from keyboard
Markers
. . . . . . . . . . . . . . . . . . . . . Marker Control Menu
Mrkr Mode . . . . . . . . . . . . . . . . . . . Select Marker Mode
Mrk1 Pos . . . . . . . . . . . . . . . . . . . . Set Marker 1 position
Mrk2 Pos . . . . . . . . . . . . . . . . . . . . Set Marker 2 position
Trig/Time
. . . . . . . . . . . . . . . . . . . . . Trigger / Time Configuration Menu
Time Span . . . . . . . . . . . . . . . . . . . Select measurement time span
Trig Pos. . . . . . . . . . . . . . . . . . . . . . Select trigger position (Pulse Mode only)
TrigDelay . . . . . . . . . . . . . . . . . . . . Set trigger delay time (Pulse Mode only)
TrigLevel . . . . . . . . . . . . . . . . . . . . . Set trigger level (Pulse Mode only)
TrigSlope . . . . . . . . . . . . . . . . . . . . Select trigger slope (Pulse Mode only)
HoldOff
. . . . . . . . . . . . . . . . . . . . . Set trigger holdoff time (Pulse Mode only)
Trig Srce . . . . . . . . . . . . . . . . . . . . . Select trigger source
Trig Mode . . . . . . . . . . . . . . . . . . . . Select trigger mode
Statisticl
. . . . . . . . . . . . . . . . . . . . . Statistical Mode Configuration Menu
Horz Span . . . . . . . . . . . . . . . . . . . Select horizontal axis sensitivity
% Offset . . . . . . . . . . . . . . . . . . . . . Set horizontal axis display center
Stat Mode . . . . . . . . . . . . . . . . . . . . Select mode
TrmCount . . . . . . . . . . . . . . . . . . . . Set number of samples to acquire
TrmAction . . . . . . . . . . . . . . . . . . . . Select action at TermCount
Calibratr
. . . . . . . . . . . . . . . . . . . . . Calibration Control Menu
[Int | Ext] Signal . . . . . . . . . . . . . . . Select output signal
Level
. . . . . . . . . . . . . . . . . . . . . Set calibrator output level
PlsPeriod . . . . . . . . . . . . . . . . . . . . Select Pulse Period (external calibrator only)
DutyCycle . . . . . . . . . . . . . . . . . . . . Select Pulse Duty Cycle (external calibrator only)
[Int | Ext] Status . . . . . . . . . . . . . . . View status of internal/external calibrator
Select [Int | Ext] . . . . . . . . . . . . . . . Select internal/external calibrator
Save/Recl
. . . . . . . . . . . . . . . . . . . . . Instrument Save/Recall Menu
SetupSave . . . . . . . . . . . . . . . . . . . Save current setup to memory[1,2,3,4]
SetupRecl . . . . . . . . . . . . . . . . . . . . Recall current setup from memory[1,2,3,4]
Table 3-5. Main Menu Summary - (Cont)