Table 4-1 remote command summary (cont) – Boonton 4530 Peak Power Meter User Manual User Manual
Page 133

4-59
Boonton Electronics
Chapter 4
4530 Series RF Power Meter
Remote Operation
SENSe[1 | 2]:PULse:DISTal
set/return pulse distal level in percent of top power,
SENSe[1 | 2]:PULse:MESIal
set/return pulse mesial level in percent of top power,
SENSe[1 | 2]:PULse:PROXimal
set/return pulse proximal level in % of top power,
SENSe[1 | 2]:PULse:UNITs
set/return power units used for DIST, MESI and PROX arguments
SENSe[1 | 2]:PULse:STARTGT
set/return pulse gate start in % of pulse duration,
SENSe[1 | 2]:PULse:ENDGT
set/return pulse gate end in % of pulse duration,
SENSe[1 | 2]:HIST:COUNt
set/return the number of histogram bins to return,
SENSe[1 | 2]:HIST:INDEX
set/return index of first histogram bin to return,
SENSe[1 | 2]:HIST:DATA?
return “count” bin values from the signal histogram, starting at “index”
SENSe[1 | 2]:CALTAB:COUNt
set/return the number of cal table values to return,
SENSe[1 | 2]:CALTAB:INDEX
set/return index of first cal table value to return,
SENSe[1 | 2]:CALTAB:DATA?
return “count” power values from the cal table, starting at “index”.
SENSe[1 | 2]:MBUF:SIZe
set/return the number readings needed to fill meas buffer,
SENSe[1 | 2]:MBUF:RATe
set/return meas buffer rate for Mod & CW,
SENSe[1 | 2]:MBUF:POSition?
return current acquisition index position of measurement buffer
SENSe[1 | 2]:MBUF:COUNt
set/return the number of meas buffer readings to return,
SENSe[1 | 2]:MBUF:INDEX
set/return index of first meas buffer reading to return,
SENSe[1 | 2]:MBUF:DATA?
return “count” stored readings from the meas buffer, starting at “index”
SENSe[1 | 2]:SBUF:MODE
set/return status of user defined sample buffer,
SENSe[1 | 2]:SBUF:PERiod
set/return the A/D sampling period,
SENSe[1 | 2]:SBUF:PREsamp
set/return the number of samples before the trigger,
SENSe[1 | 2]:SBUF:POSTsamp
set/return the number of samples after the trigger,
SENSe[1 | 2]:SBUF:COUNt
set/return the total number of samples to return,
SENSe[1 | 2]:SBUF:INDEX
set/return the index of next data point relative to trigger position
SENSe[1 | 2]:SBUF:DATA?
return “count” power samples from captured buffer starting at “index”.
SENSe[1 | 2]:TEMPerature?
return sensor internal temperature in degrees Celsius
SENSe[1 | 2]:CALTemp?
return sensor calibration temperature in degrees Celsius
STATus:PRESet
set device dependent SCPI and device status registers
STATus:OPERation:EVENt?
return value of Operation Status Register
STATus:OPERation:CONDition?
return value of Operation Condition Register (unlatched)
STATus:OPERation:ENABle
set/return value of Operation Enable Mask,
STATus:QUEStionable:EVENt?
return value of Questionable Status Register
STATus:QUEStionable:CONDition?
return value of Questionable Condition Register (unlatched)
STATus:QUEStionable:ENABle
set/return value of Questionable Enable Mask,
SYSTem:BEEP
set/return keypad audible beeper status,
SYSTem:ERRor[:NEXT]?
return next queued error code number and description
SYSTem:COMMunicate:SERial:BAUD
set/return serial port baud rate,
SYSTem:COMMunicate:SERial:BITS
set/return number of serial port data bits,
SYSTem:COMMunicate:SERial:SBITs
set/return number of serial port stop bits,
SYSTem:COMMunicate:SERial:PARity
set/return state of serial port parity bit,
SYSTem:COMMunicate:SERial:CONTrol:RTS
set/return serial RTS handshake mode: OFF, ON
Table 4-1 Remote Command Summary (Cont)