beautypg.com

Configuration replication utility, Hp rom-based setup utility, Using rbsu – HP ProLiant DL360 G5 Server User Manual

Page 68: Auto-configuration process, If the con, Hp rom, Based setup utility, To con

background image

Configuration and utilities 68

For more information, and to download the SmartStart Scripting Toolkit, refer to the HP website
(

http://www.hp.com/servers/sstoolkit

).

Configuration Replication Utility

ConRep is shipped in the SmartStart Scripting Toolkit and is a program that works with RBSU to replicate
hardware configuration on ProLiant servers. This utility is run during State 0, Run Hardware Configuration
Utility, when doing a scripted server deployment. ConRep reads the state of the system environment
variables to determine the configuration and then writes the results to an editable script file. This file can
then be deployed across multiple servers with similar hardware and software components. For more
information, refer to the SmartStart Scripting Toolkit User Guide on the HP website
(

http://h18004.www1.hp.com/products/servers/management/toolkit/documentation.html

).

HP ROM-Based Setup Utility

RBSU, an embedded configuration utility, performs a wide range of configuration activities that may
include:

Configuring system devices and installed options

Displaying system information

Selecting the primary boot controller

Configuring memory options

Language selection

For more information on RBSU, refer to the HP ROM-Based Setup Utility User Guide on the Documentation
CD or the HP website (

http://www.hp.com/servers/smartstart

).

Using RBSU

The first time you power up the server, the system prompts you to enter RBSU and select a language.
Default configuration settings are made at this time and can be changed later. Most of the features in
RBSU are not required to set up the server.

To navigate RBSU, use the following keys:

To access RBSU, press the F9 key during power up when prompted in the upper right corner of the
screen.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt

you for confirmation of settings before you exit the utility. To change a selected setting, you must select a
different setting and press the Enter key.

Auto-configuration process

The auto-configuration process automatically runs when you boot the server for the first time. During the
power-up sequence, the system ROM automatically configures the entire system without needing any
intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a
default setting based on the number of drives connected to the server.

NOTE: The server may not support all the following examples.

NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically

configure the array. You must run ORCA to configure the array settings.