HP ProLiant DL360 G5 Server User Manual
Page 14
Component identification 14
HP Systems Insight
Display LED and color
Internal health LED
color
Status
Processor failure, socket X
(amber)
Red
One or more of the following conditions may exist:
•
Processor in socket X has failed.
•
Processor X is required yet not installed in the socket.
•
Processor X is unsupported.
Amber
Processor in socket X is in a pre-failure condition.
Processor failure, both
sockets (amber)
Red
Processor types are mismatched.
PPM failure (amber)
Red
Integrated PPM has failed.
FBDIMM failure, slot X
(amber)
Red
One or more of the following conditions may exist:
•
FBDIMM in slot X has failed.
•
FBDIMM in slot X is an unsupported type, and no
valid memory exists in another bank.
Amber
One or more of the following conditions may exist:
•
FBDIMM in slot X has reached single-bit correctable
error threshold.
•
FBDIMM in slot X is in a pre-failure condition.
•
FBDIMM in slot X is an unsupported type, but valid
memory exists in another bank.
FBDIMM failure, all slots
(amber)
Red
No valid or usable memory is installed in the system.
Overtemperature (amber) Amber
The health driver has detected a cautionary temperature
level.
Red
The server has detected a critical temperature level.
Riser interlock (amber)
Red
The PCI riser board assembly is not seated properly.
Online spare memory
(amber)
Amber Bank
X failed over to the online spare memory bank.
Fan module (amber)
Amber
A redundant fan has failed.
Fan module (amber)
Red
The minimum fan requirements are not being met in one
or more of the fan modules. One or more fans have failed
or are missing.