beautypg.com

HP ProLiant DL360 G5 Server User Manual

Page 14

background image

Component identification 14

HP Systems Insight
Display LED and color

Internal health LED
color

Status

Processor failure, socket X
(amber)

Red

One or more of the following conditions may exist:

Processor in socket X has failed.

Processor X is required yet not installed in the socket.

Processor X is unsupported.

Amber

Processor in socket X is in a pre-failure condition.

Processor failure, both
sockets (amber)

Red

Processor types are mismatched.

PPM failure (amber)

Red

Integrated PPM has failed.

FBDIMM failure, slot X
(amber)

Red

One or more of the following conditions may exist:

FBDIMM in slot X has failed.

FBDIMM in slot X is an unsupported type, and no
valid memory exists in another bank.

Amber

One or more of the following conditions may exist:

FBDIMM in slot X has reached single-bit correctable
error threshold.

FBDIMM in slot X is in a pre-failure condition.

FBDIMM in slot X is an unsupported type, but valid
memory exists in another bank.

FBDIMM failure, all slots
(amber)

Red

No valid or usable memory is installed in the system.

Overtemperature (amber) Amber

The health driver has detected a cautionary temperature
level.

Red

The server has detected a critical temperature level.

Riser interlock (amber)

Red

The PCI riser board assembly is not seated properly.

Online spare memory
(amber)

Amber Bank

X failed over to the online spare memory bank.

Fan module (amber)

Amber

A redundant fan has failed.

Fan module (amber)

Red

The minimum fan requirements are not being met in one
or more of the fan modules. One or more fans have failed
or are missing.